HOST SOFTWARE INTERFACE

Summary

COMMAND NAME

COMMAND CODE

 

 

 

 

 

PARAMETERS USED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

b6

b5

b4

b3

b2

b1

b0

 

F

SC

SN

C

SDH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recalibrate

 

0

0

0

1

x

x

x

x

 

N

N

N

N

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read Sector(s)

 

0

0

1

0

0

0

L

x

 

N

Y

Y

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read DMA

 

1

1

0

0

1

0

0

x

 

N

Y

Y

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write Sector(s)

 

0

0

1

1

0

0

L

x

 

N

Y

Y

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write DMA

 

1

1

0

0

1

0

1

x

 

N

Y

Y

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write Verify Sector(s)

 

0

0

1

1

1

1

0

0

 

N

Y

Y

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read Verify Sector(s)

 

0

1

0

0

0

0

0

x

 

N

Y

Y

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format Track

 

0

1

0

1

0

0

0

0

 

N

N

N

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Seek

 

0

1

1

1

x

x

x

x

 

N

N

Y

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Execute Diagnostic

 

1

0

0

1

0

0

0

0

 

N

N

N

N

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initialize Parameters

 

1

0

0

1

0

0

0

1

 

N

Y

N

N

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read Sector Buffer

 

1

1

1

0

0

1

0

0

 

N

N

N

N

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write Sector Buffer

 

1

1

1

0

1

0

0

0

 

N

N

N

N

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Identify Drive

 

1

1

1

0

1

1

0

0

 

N

N

N

N

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Features

 

1

1

1

0

1

1

1

1

 

Y

N

N

N

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read Multiple

 

1

1

0

0

0

1

0

0

 

N

Y

Y

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write Multiple

 

1

1

0

0

0

1

0

1

 

N

Y

Y

Y

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Multiple Mode

 

1

1

0

0

0

1

1

0

 

N

Y

N

N

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIMER VALUE

TIME-OUT PERIOD

0

Time-out disabled

1 - 240

(value * 5) seconds

241 - 251

((value - 240) * 30) minutes

252

21 minutes

253

Vendor unique period = 10 hours

254

Reserved

255

21 minutes, 15 seconds

6 – 4

Page 46
Image 46
Maxtor VL 17 manual Summary, Command Name Command Code Parameters Used, Timer Value TIME-OUT Period