18.Open the gas shut off valve inside the upper dryer (see figures 42 & 43), and check the union connectionto the gas valve for leaks using a soap solution, DO NOT use an open flame to check for gas leaks. If bubbles occur, tighten the connectionsand recheck. Make sure not to let solution drip into any electrical connector or component.
NOTE: As a courtesy, many local gas utilities will inspect a gas appliance installation. Check with your local utilityto see if this service is provided in your area.
NOTE: The minimum permissible gas (naturalor mixed)supply pressure for purposes of input adjustment is 4.5 inchesof water.
Figure42Figure43
19.Removewire harnessesand plastic clips from base (see figure 44) and connect each harnessto the connector in the washer making sure locking tabs are engaged, and harness is tucked out of the way of the dispenser. (See figures 45 & 46.)
Figure 45
7 | ii_i ii |
Figure 44
L
Figure 46
Page 19