Necessary element conversion parts are located in a small bag contained within the large plastic manual envelope attached to the side of the water heater.

Necessary element conversion parts are located in a small bag contained within the large plastic manual envelope attached to the side of the water heater.

FIGURE 12.

1.Before beginning the conversion turn “OFF” electric power supply to the water heater.

FIGURE 13.

2.The convertible element is located behind the lower access panel of the water heater. Remove the two screws securing the access panel, and remove panel.

FIGURE 14.

3.Remove the insulation cap with handle to expose the terminal cover.

FIGURE 15.

4.Lower Element: Lift out the tab as shown to unclip the terminal cover from the thermostat. The terminal cover can now be removed from the thermostat.

FIGURE 16.

5.Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.

FIGURE 17.

6.The buss bar is labeled 5500 W. Place the buss bar over terminals 2 and 3 with the 5500 W visible. Install the extra screw provided into terminal 3.

FIGURE 18.

7.The wire removed from terminal 2 has a looped end. It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal 2, and secured using the remaining screw.

FIGURE 19.