Instructions for Installation (cont’d)
Converting the Lower Element (cont’d)
1.Before beginning the conversion turn “OFF” electric power supply to the water heater.
4.Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.
WARNING
HAZARD OF ELECTRICAL SHOCK! Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned “OFF”. FAILURE TO DO THIS COULD RESULT IN DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
2.The convertible element is located behind the lower access panel of the water heater. Remove the screw securing the access panel, and remove panel.
3. Remove the insulation pad to expose the opening.
5.The buss bar is labeled 5500 W. Place the buss bar over ter- minals 2 and 3 with the 5500 W visible. Install the extra screw provided into terminal 3.
5500 W
6.The wire removed from terminal 2 has a looped end. It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal 2, and secured using the remaining screw.
7.Tighten terminals 2 and 3 to ensure proper electrical con- nection.
WARNING
Failure to tighten terminal screws can cause a fire which can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
13