Maytag HRE3966T manual Converting the Lower Element cont’d, Instructions for Installation cont’d

Models: HRE3950S HRE2940S HRE3930T HRE2966T HRE3940L HRE3940T HRE2940L HRE3940S HRE2930T HRE2950S HRE2940T HRE2950T HRE3950T HRE3966T

1 36
Download 36 pages 25.01 Kb
Page 14
Image 14
Converting the Lower Element (cont’d)

Instructions for Installation (cont’d)

Converting the Lower Element (cont’d)

1.Before beginning the conversion turn “OFF” electric power supply to the water heater.

4.Lift out the tab as shown to unclip the terminal cover from the thermostat. The terminal cover can now be removed from the thermostat.

Lift out tab to unclip terminal cover from thermostat.

Manual background WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned “OFF”. FAILURE TO DO THIS COULD RESULT IN DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

2.The convertible element is located behind the lower access panel of the water heater. Remove the two screws securing the access panel, and remove panel.

3.Remove the block of insulation and pad to expose the terminal cover.

5.Remove the screws from terminal 2 of the element, and move the looped end of the wire aside.

6.The buss bar is labeled 5500 W. Place the buss bar over ter- minals 2 and 3 with the 5500 W visible. Install the extra screw provided into terminal 3.

5500 W

14

Page 14
Image 14
Maytag HRE3966T, HRE3950T, HRE2950T, HRE2940T manual Converting the Lower Element cont’d, Instructions for Installation cont’d