Instructions for Installation (cont’d)
Converting the Lower Element (cont’d)
7.The wire removed from terminal 2 has a looped end. It must remain looped and now be placed (as shown) on top of the buss bar, over the opening of terminal 2, and secured using the remaining screw.
8.Tighten terminals 2 and 3 to ensure proper electrical con- nection.
WARNING
Failure to tighten terminal screws can cause a fire which can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
9.Replace the terminal cover on the thermostat making sure that the locking tabs on the terminal cover are in place.
WARNING
Make sure the thermostat is flush against the tank, the terminal cover is in place, and the insulation is replaced. Failure to do so can result in DEATH, SERI-
OUS BODILY INJURY, OR PROPERTY DAMAGE.
10.Place the insulation block and pad back in place so that it completely covers the thermostat and element.
11. Replace the access panel.
12.Complete wiring to the water heater, or if completed, turn “ON” electric power to the water heater after filling the tank with water.
CAUTION
Never use this water heater unless it is completely full of water. To prevent damage to the tank and heating element, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” power.
15