FIGURE 1 - UNIT CUTAWAY

349687-JTG-A-1007

UNIT

FIGURE 1 - UNIT CUTAWAY

with aluminized steel or optional stainless steel tubes, a

ble of introducing up to 100% outdoor air with nominal

redundant gas valve, spark ignition, power venting, an

1% leakage type dampers.

ignition module for 100% shut-off and all of the safety

The enthalpy system contains one sensor that monitors

controls required to meet the latest ANSI standards.

the outdoor air and determines when the air is cool

The gas supply piping can be routed into the heating

enough and dry enough to provide free cooling.

compartment through a hole in the base pan of the unit

The rainhood is painted to match the basic unit and must

or through a knockout in the piping panel on the front of

be field-assembled before installing.

the unit.

 

Electric Heat Operation - All electric heat models (fac-

BAS-READY ECONOMIZER - Includes a slide-in / plug-

in damper assembly with fully modulating spring-return

tory installed only) are wired for a single power source

motor actuator with zero to 95-degree rotation capable of

and include a bank of nickel chromium elements

introducing up to 100% outdoor air with nominal 1% leak-

mounted at the discharge of the supply air blower to pro-

age type dampers.

vide a high velocity and uniform distribution of air across

 

the heating elements. Every element is fully protected

Actuator requires 2-10 VDC input from an external

against excessive current and temperature by fuses and

source, such as a field-installed or factory-installed BAS

two thermal limit switches.

controller. BAS-ready actuators have an adjustable auxil-

The power supply wiring can be routed into the control

iary end-switch for optional power exhaust control.

 

box through a threaded pipe connection in the base pan

For units with optional VAV control, a factory-installed,

of the unit or through a knockout in the wiring panel on

dry bulb sensor determines if outdoor air temperature is

the front of the unit.

low enough to provide free-cooling operation. (Field-

FACTORY-INSTALLED OPTIONS

installed humidity sensors for either outdoor air or out-

door & return air streams are available for single

SINGLE INPUT ELECTRONIC ENTHALPY ECONO-

enthalpy and differential enthalpy configurations, respec-

tively).

MIZERS - Includes a slide-in / plug-in damper assembly

 

with fully modulating spring-return motor actuator capa-

The rainhood is painted to match the basic unit and must

 

be field-assembled before installing.