USE WITHOUT POWER CORD

USE WITHOUT POWER CORD

If power cord cannot be used, then follow these wiring instructions.

Provide a way to easily shut off the electric power when working on the water heater. This could be with a circuit breaker or fuse block in the entrance box or a separate disconnect switch.

Install and connect a circuit directly from the main fuse or circuit breaker box. This circuit must be the right size and have its own fuse or circuit breaker.

A standard 1/2” conduit opening has been made in the water heater junction box for the conduit connection.

Use wire nuts and connect the power supply wiring to the wires inside the water heater’s junction box.

The water heater must be electrically “grounded” by the installer. The unit will not operate unless it is properly grounded. A green ground screw has been provided on the water heater’s junction box. Connect ground wire to this location. For complete grounding details and all allowable exceptions, refer to the current edition of the National

Electrical Code, ANSI/NFPA 70.

FIGURE26.

Wiring Diagram

NOTE: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING

CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS

OPERATION. VERIFY PROPER OPERATIONAFTER SERVICING.