TROUBLESHOOTING (Continued)

TROUBLESHOOTING (Continued)

This troubleshooting guide has been supplied for use by qualified service personnel who have a complete understanding of both electricity and gas.

Label all wiring before disconnecting any wiring; to ensure correct reconnection. Failure to follow this instruction could cause improper and possible dangerous operation, resulting in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

THERMOSTAT AND GAS SUPPLY CHECK

NO

Turn “ON” gas supply.

Is gas being supplied to the thermostat?

YES

Is thermostat calling for heat? Run (HOT) water from heater and set adjustment button higher. Check using a manometer at thermostat pressure tap.

YES

Call gas company to increase gas pressure.

Is there a minimum gas pressure 4” W.C. for natural gas or 10” W.C. for propane (L.P.) gas?

THERMOSTAT AND GAS SUPPLY CHECK NOManual backgroundManual backgroundManual backgroundManual background NO

YES

GO TO SYSTEM CHECK

SECTION, PAGE 39.