Recessed Area and Closet Installation Instructions
Product Dimensions 686 mm (27") dryer
This dryer may be installed in a recessed area or closet. This dryer must not be installed behind a lockable door, a sliding door, or a door with a hinge on the opposite side to that on the dryer.
The installation spacing is in millimeters and is the minimum allowable. Additional spacing should be considered for ease of installation, servicing, and compliance with local codes and ordinances.
If installed in a closet with a door, the minimum unobstructed air opening in the top and bottom is required. Louvered doors with equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
No other
Minimum Installation Clearances
356 mm (14") max.
381 mm
| 686 mm (27") | ||
| ELECTRIC | 356 mm | |
|
| ||
|
| (14") | |
| BACK VIEW | ||
152 mm | 330 mm | 102 mm (4") | |
(63⁄4") | (13") | ||
dia. | |||
|
| ||
| GAS |
| |
|
| EXHAUST | |
32 mm |
|
| |
(11⁄4") |
|
| |
| 743 mm (291/4") | ||
| 673 mm (261/2") |
940 mm
(37")
121mm
(43⁄4")
(15")*Closet door
0 mm (0")
0 mm (0") | 0 mm (0") |
25 mm (1")
Recessed front view | Closet side view |
Additional clearances for wall, door, and floor moldings may be required or if external exhaust elbow is used.
200 mm (77⁄8")
SIDE VIEW
889 mm
(35")
310cm2
(48 in2.)*
Front
View
155cm2 (24 in2.)*
closet
door
76 mm (3")
*Opening is the minimum for a closet door. Louvered doors with equivalent air openings are acceptable.
76 mm (3")
25mm (1")