Maytag Refrigerator General Use Conditions, System Specification and Performance Data Sheet

Models: Refrigerator

1 36
Download 36 pages 59.16 Kb
Page 22
Image 22
System Specification and Performance Data Sheet

WaterFilter

System Specification and Performance Data Sheet

Refrigerator Water Filter Cartridge Model UKF8OO1AXX

Specifications

Service

Flow Rate

(Maximum)

0 78 GPM

(2.9 L/min)

Rated

Service Life

UKF8001AXX-750 (Maximum)

750 gallons/2838 liters

Maximum

Operating

Temperature

100° F/38 ° C

Minimum

Pressure

 

Requirement

35 psi/241

kPA

Minimum

Operating

Temperature

33° F/l° C

Maximum

Operating

Pressure

120 psi/

827 kPA

Performance Data

Pen_PuFe

1000 Apollo Road

Eagan, Minnesota 55121-2240

651.450.4913 EPA EST #35917-MN-1

100834/B

 

 

 

 

 

 

 

 

 

 

 

Standard No. 42: Aesthetic Effects

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USEPA

 

 

 

 

Influent

 

Influent

 

 

 

 

Effluent

 

 

% Reduction

 

Min.

Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

 

 

MCL

 

 

Challenge

 

Concentration

Average

 

Average

 

Maximum

Average

 

Minimum

Reduction

Chlorine

 

 

 

 

 

 

 

 

 

 

2.0

mg/L

±

10%

1.88 mg/L

<0.05136364

mg/L

0.06

mg/L

>97.26%

 

96.84%

 

50%

T&O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Particulate **

 

 

 

 

 

 

at

least 10,000

particles/ml

5,700,000

#/ml

30,583

#/ml

69,000

#/ml

99.52%

 

98.94%

 

85%

 

 

 

 

 

 

 

 

 

 

 

Standard

No.

53: Health Effects

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USEPA

 

 

 

 

Influent

 

Influent

 

 

 

 

Effluent

 

 

% Reduction

 

Min.

Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

 

 

MCL

 

 

Challenge

 

 

Concentration

Average

 

Average

Maximum

Average

 

Minimum

Reduction

Turbidity

 

 

 

1 NTU**

 

 

 

11 ±

 

1 NTU***

10.7 NTU

 

0.31 NTU

.049

NTU

9709%

 

95.20%

0.5 NTU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cysts

 

 

 

 

99.5%

Reduction

 

 

Minimum

 

50,000/L

166,500 #/L

 

<1

 

#/L

 

<1

 

#/L

>99.99%

 

>99.99%

>99.95%

Asbestos

 

 

 

99%

Reduction

10'10_ fibers/L; fibers >10 micrometers in length

155

MF/L

 

<1

MF/L

<1

MF/L

>99.99%

 

>99.99o/o

 

99%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lead

at

pH

6.5

 

0.015

mg/L

 

 

 

0.15

mg/L

+

10%

0.153 mg/L

<.001

mg/L

<.001

mg/L

>99.35o/o

 

>99.29o/o

0.10 mg/L

Lead

at

pH

8.5

 

0.015

mg/L

 

 

 

0.15

mg/L

+

10%

0.150

mg/L

<.001

mg/L

<.001

mg/L

>99.33o/o

 

>99.29o/o

0.10 mg/L

Mercury

at

pH

6,5

0.002

mg/L

 

 

 

.006

mg/L

±

10%

0.006

mg/L

0.0003

mg/L

0.0005 mg/L

95.70%

 

90.91%

0.002 mg/L

Mercury

at

pH

8.5

0.002

mg/L

 

 

 

.006

mg/L

±

10%

0.006

mg/L

0.0008

mg/L

0.0015

mg/L

86.22%

 

75.93o/o

0.002 mg/L

Atrazine

 

 

 

0.003

mg/L

 

 

0.009

 

mg/L

+

10%

0.009

mg/L

<0.002

mg/L

0.002 mg/L

76.99%

 

75.31%

0.003 mg/L

Benzene

 

 

 

0.005

mg/L

 

 

0.015

 

mg/L

±

10%

0.014

mg/L

0.0006

mg/L

0.0011

mg/L

95.71o/o

 

92.14o/o

0.005 mg/L

Carbofuran

 

 

0.04

mg/L

 

 

 

0.08

mg/L

±

10%

0.081

mg/L

<0.001

mg/L

<0.001

mg/L

98.74%

 

98.46%

0.04 mg/L

p-Dichlorobenzene

 

0.075

mg/L

 

 

 

.225

mg/L

±

10%

0.208

mg/L

<0.0005

mg/L

<0.0005

mg/L

99.76%

 

99.74%

0.075 mg/L

Lindane

 

 

 

0.0002

mg/L

 

 

0.002

 

mg/L

+

10%

0.002 mg/L

0.000 mg/L

<0.0001

mg/L

98.72%

 

96.50%

0.0002 mg/L

Toxaphene

 

 

0.003

mg/L

 

 

 

0.015

±

10o/o

0.015

mg/L

<0.001

mg/L

<0.001

mg/L

92.97%

 

91.67%

0.003 mg/L

*

Tested

using

a flow rate

of

0.78 gpm;

pressure

of

60

psig;

pH

of 7.5 + 0.5;temp.

of

Tested

and

 

certified

by NSF

IntemaUonal

against

ANSI/NSF

Standards

42 & 53

 

68 ° +

5 ° F (20 ° +

3 ° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in

models

 

UKFSOOtAXX-750

 

for the

reduction

of:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**

Measurement

in

Particles/mh

Particles

used were

0.5

-

1 microns

 

Standard

No.

42:

Aesthetic

 

Effects

Standard

No.

53:

Health

Effects

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

***

NTU - Nephelometric

Turbidi b, Units

 

 

 

 

 

 

 

 

 

Taste and

Odor

Reduction

 

 

Chemical

Reduction

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chlorine

Taste

& Odor

 

 

Lead, Atrazine,

Lindane,

Benzene,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mechanical

 

Filtration

Unit

 

 

Carbofuran.

p-Dichlorobenzene,

Mercury

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Particulate

Reduction

Class

 

1

& Toxaphene

Reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mechanical

Filtration

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cyst. Turbidity and Asbestos Reduction

General Use Conditions

Read this Performance Data Sheet and compare the

capabilities of this unit with your actual water treatment needs.

DO NOT use this product where water is microbiologic- ally unsafe or of unknown quality without adequate disinfection before or after the system. System certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

USE ONLY WITH COLD WATER SUPPLY. CHECK FOR COMPLIANCE WITH THE STATEAND LOCAL LAWS

AND REGULATIONS.

The PuriClean_ II retractable water filtration system uses a UKF8001AXX replacement cartridge. Timely replacement of filter cartridge is essential for performance satisfaction from this filtration system. Please refer to the applicable section of your Use & Care Guide for general operation, maintenance requirements and troubleshooting. Suggested retail price of replacement water filter is $39.99.

This system has been tested according to ANSI/NSF 42 and 53 for reduction of the substance listed above. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42 and 53.

21

Page 22
Image 22
Maytag Refrigerator General Use Conditions, System Specification and Performance Data Sheet, Specifications, WaterFilter