Installation

Installation

 

 

 

 

 

 

 

The MC303 can be placed upright on a table or shelf,

 

sure to cut out a ventilation hole in the mounting shelf ac-

standing on its four feet. It also can be custom installed in

cording to the dimensions in the drawing.

 

a piece of furniture or cabinet of your choice. The four feet

1 When the MC303 is installed together with other McIntosh

may be removed from the bottom of the MC303 when it is

custom installed as outlined below. The four feet together

 

Components, check clearances on all components before

with the mounting screws should be retained for possible

 

proceeding.

 

 

 

future use if the MC303 is

 

 

 

 

 

 

 

removed from the custom

 

 

 

 

17-9/16"

 

 

installation and used free

 

 

 

 

44.62cm

 

 

standing. The required

 

 

 

 

 

 

 

panel cutout, ventilation

 

 

 

 

 

 

 

cutout and unit dimen-

 

 

 

 

 

 

 

sions are shown.

 

 

 

 

 

 

 

Always provide adequate

MC303 Front Panel

 

 

 

 

 

10 -13/16"

ventilation for your

 

 

 

 

 

 

 

 

 

 

27.46cm

MC303. Cool operation

Custom Cabinet Cutout

 

 

 

 

 

 

 

 

 

 

 

 

 

ensures the longest pos-

 

 

 

 

 

 

 

sible operating life for any

 

 

 

 

 

 

 

electronic instrument. Do

 

 

 

 

 

 

 

not install the MC303 di-

 

 

 

 

 

 

 

rectly above a heat gener-

 

 

 

 

 

 

 

ating component such as a

 

 

 

6"

 

 

 

high powered amplifier. If

 

Cabinet

 

 

 

 

15.24cm

Cutout Opening for Custom Mounting

all the components are in-

 

Front

 

 

 

 

 

 

 

stalled in a single cabinet,

 

Panel

 

 

 

 

 

 

 

 

 

 

 

 

a quiet running ventila-

 

 

 

 

 

 

 

tion fan can be a definite

Opening

 

 

 

 

 

asset in maintaining all

for Ventilation

 

 

 

 

 

the system components at

 

 

 

 

 

 

 

the coolest possible oper-

 

 

 

 

 

 

 

ating temperature.

 

 

 

 

 

 

 

A custom cabinet instal-

MC303 Side View

 

 

 

 

 

 

lation should provide the

in Custom Cabinet

 

 

 

 

 

 

following minimum spac-

 

 

 

 

 

 

Chassis

ing dimensions for cool

 

 

 

 

 

 

Spacers

operation.

 

 

 

 

 

 

 

Allow at least 6 inches

 

 

 

Cutout Opening for Ventilation

 

(15.24cm) above the top,

 

Support

 

 

 

 

 

2 inches (5.08cm) below

 

 

1"

 

 

 

 

Shelf

 

 

 

 

the bottom and 1 inch

 

 

 

2.54cm

 

 

 

(2.54cm) on each side of

 

 

 

 

 

 

 

the Power Amplifier, so

 

 

 

 

 

 

 

that airflow is not ob-

 

21/32"

 

14-1/2"

 

 

structed. Allow 19-1/2

MC303 Bottom View

 

36.83cm

 

15-5/16"

inches (49.53cm) depth

1.67cm

 

 

14"

in Custom Cabinet

 

 

Cutout Opening

38.91cm

behind the front panel.

 

 

35.56cm

 

 

 

 

 

 

 

for Ventilation

 

Allow 1-5/8 inch (4.12cm)

 

 

 

 

 

 

 

 

 

 

 

 

in front of the mounting

Note: Center the cutout Horizontally on the unit.

 

 

 

 

panel1 for clearance. Be

 

 

 

 

For purposes of clarity, the above

 

 

 

 

 

 

illustration is not drawn to scale.

 

 

 

 

 

6

 

 

 

 

 

 

 

Page 6
Image 6
McIntosh MC303 owner manual Installation