To Select a landmark from the database:

those in the Landmark database. Be sure to change this option back to "Astronomical" when you wish to view celestial objects again.

3.Press MODE once. "Select Item: Setup" displays.

4.Press the Scroll Down key once and "Select Item: Object" displays. Press

ENTER. "Object: Solar System" displays.

5.Press the Scroll Up key twice and "Object: Landmarks" displays. Press ENTER.

"Landmark: Select" displays.

6.Press the Scroll Down key once. "Landmark: Add" displays. Press ENTER.

7."Landmark Name" displays. Using Arrow keys, enter a name for the landmark you wish to add to the database. When finished, press ENTER.

8."Center Landmark. Press Enter" displays. Using only the Arrow keys (do not manually move the telescope), move the telescope to the desired landmark and center the object in the eyepiece. Press ENTER. The object is now stored in memory.

9."Landmark: Add" displays. If you wish to add more landmarks, repeat steps 5 through 8.

To Select a landmark from the database:

1.Make sure the telescope is located and aligned exactly as when the desired land- mark was entered into memory.

2.Display the "Landmark: Select" menu option. Press ENTER.

3.Use the Scroll keys to scroll through the list of objects you have previously entered. When the desired object displays, press ENTER to select the object.

Use the Scroll keys to scroll through location information about the object, if desired. Press GO TO to slew the telescope to the landmark.

4.Press MODE to exit.

To perform a Landmark Survey:

This procedure allows you to perform a tour of the objects entered in the "Object: Landmark" menu option—note that the Landmark Survey will function only if you have previously entered objects in the Landmark menu.

1.Navigate to "Utilities: Landmark Survey" menu and press ENTER.

2."Landmark Survey: Slewing..." displays. The telescope moves to the first object on the Survey list and displays the name of the object.

3.Press MODE to stop the Survey. Press ENTER to restart the survey at the first object of the survey.

To check on the available amount of memory in AutoStar II:

AutoStar II has a limited amount of memory. Once you begin to store Landmarks, user objects and other bits of information in AutoStar II, you will begin to use up memory. This procedure allows you to check on how much memory is still available.

1.Navigate to the "Setup: Statistics" menu option and press ENTER.

2."Statistics: 37.2K Char. Free" displays. This is the amount of memory that is still available to the user.

Identify

This procedure allows you to use AutoStar II to identify objects you have found in the night sky using the Arrow keys. If the object is not in AutoStar II's database, AutoStar

IIdisplays information about an object in its database that is closest to the one you queried about.

Important Note: For this function to operate properly, you must first ini- tialize and align AutoStar II. If you physically move the telescope after ini- tialization, this function will fail to operate properly.

- 35 -

Looking at or near the Sun will cause irreversible damage to your eye. Do not point this tele-

 

scope at or near the Sun. Do not look through the telescope as it is moving.