selects all objects from very poor through super — what could be considered an “ALL” setting. The object quality symbols are:

Quality Symbol

Symbol Description

SU

Super

EX

Excellent

VG

Very Good

G

Good

FR

Fair

PR

Poor

VP

Very Poor

For example: to define the visual object quality range to very good and better, press the ENTER key until the symbol VG is displayed. From the VP setting to VG requires three ENTER key presses. The CDS will now select objects that look Very Good through Super.

c) HIGHER

The Higher option sets the horizon setting for the telescope. At power up, the setting is 00 degrees, which assumes the CDS system has an unobstructed, line-of-site view to the horizon in every direction. If, however, there are things obstructing a level horizon, or if the sky quality is poor due to haze or light pollution, an artificial horizon level may be set to avoid the "undesirable" area.

To roughly judge how many degrees of the sky is "undesirable" for viewing, or is being obstructed, hold your fist at arm’s length and attempt to cover the obstruction with your fist. Each fist diameter is approximately 5 degrees. So, if a tree is three fists high, enter a setting of 15 degrees in the HIGHER setting. Once the setting has been entered using the keypad, press ENTER.

d) LARGER

The LARGER option allows an observer to set the lower apparent size limit of the objects to be observed. At power up the LARGER option is set to 000' (arc minutes). To decide what size limits to impose, it helps to have a clear understanding of exactly what an arc minute of sky is. A good example is the apparent size of the Moon, which could be expressed as 1/2 of a degree, 30 arc minutes, or 1800 arc seconds. Each arc minute is 60 arc seconds, and there are 60 arc minutes for each degree of sky.

Some beginning observers have a tough time discerning objects less than about 1 arc minute in size unless it is a double star or a planet. Astrophotographers and those involved with CCD imaging may want to set a higher value based on desired image scale coverage that would be most impressive with different films or types of CCD cameras. Enter the new value in arc minutes using the Keypad, then press ENTER.

e) SMALLER

The SMALLER option is the upper size object limit. At power up the SMALLER setting is 200' arc minutes or 3.33 degrees. This setting is high enough to cover the largest objects in the OBJECT LIBRARY. You may want to lower the value because of true field- of-view limitations of a particular eyepiece (see the RADIUS parameter option for calculating true field).

Other reasons for limiting the SMALLER value is for astrophotographic or CCD imaging requirements where a user does not want an object to exceed the imaging area of the film or the CCD chip.

f) BRIGHTER

A user may wish to adjust the BRIGHTER (magnitude) level to a brighter value, perhaps the limiting visual magnitude of the telescope being used, (approximately 14.0 for an 7" and 12.0 for a 4"). Sky conditions also greatly affect the limiting magnitude due to atmospheric haze, high clouds, light pollution, or combinations thereof.

g) FAINTER

The upper level of brightness may be adjusted with the FAINTER option, although there are few applications for limiting the CDS to a lower value.

h) RADIUS

The RADIUS value sets the boundaries of what and how many objects the CDS recognizes within a given eyepiece while in the FIELD menu selection. At power up the RADIUS option is set to 15 arc minutes, the radius of 1/2 a degree (30 arc minutes).

To calculate the true field of an eyepiece in the telescope, first divide the focal length of the telescope (e.g. 1140mm for an 5" 127ED) by the focal length of the eyepiece (for example, a 26mm Super Plössl eyepiece: 1140 divided by 26 equals 44X magnification). Then, find the apparent field of the eyepiece (which is 52 degrees for the 26mm Super Plössl) and divide it by the magnification (52 divided by 44 equals .1.18 degrees. To convert degrees to arc minutes, multiply the amount by 60, which equals 70.8 arc minutes.

To get the radius of the true field of view, divide the true field by 2. In the case of the above equation, 70.8 arc minutes divided by 2 equals 35.4 arc minutes.

2. MODE TWO: COORDINATES/GO TO

Mode Two allows a user to see where the CDS is pointing in two celestial coordinate formats, either Right Ascension and Declination or Altazimuth. Also in this mode it is possible to enter new Right Ascension and Declination coordinates for any sky position, perhaps to locate objects not in the CDS library (e.g., comets or asteroids) and have the telescope slew to the new coordinates.

A. Coordinates Menu Option

This option displays the R.A. and DEC coordinates of where the telescope is pointing. If the CDS is moved using the "N", "S", "W" or "E" keys, the coordinate display immediately updates the new position in Right Ascension and Declination.

Pressing ENTER displays the Altazimuth coordinates (ALT = and AZ =). This data is for general information only. With the ALT AZ information displayed, pressing the GO TO key will not move the telescope. Return to the R.A. and DEC coordinates by pressing the ENTER key again.

The R.A. coordinates are displayed in hours, minutes, and seconds. The DEC coordinates are displayed in degrees, minutes and seconds. The "+" represents North Declination and "-" represents South Declination. See Display 28:

RA = 02:45.54

DEC = +22°54:02

Display 28

B. GO TO Menu Option

The lower brightness limits based on stellar magnitude can be limited in the BRIGHTER option. At power up, the magnitude value is set to a very faint level of +20.0.

The GO TO option allows a user to enter Right Ascension and Declination coordinates of any object in the sky. With this ability,