METRObility Optical Systems R200 Platform Technical Specifications, Topology Solutions, Power

Models: R200

1 12
Download 12 pages 3.53 Kb
Page 9
Image 9
Platform Technical Specifications

UserThis section containsGuideinformation regarding the technical specifications and warranty for the Radiance R200 Premise Service Platform.

Platform Technical Specifications

Power

Input

R200-AC _________________________________ 100-250V AC, 50/60Hz

R200-DC _______________________________________ 48V DC (SELV)

Output ____________________________________________ 5V DC, 2A, 10W

Environmental

Operating Temperature ____________________________________ 0° to 50° C

Storage Temperature ____________________________________ -25° to 70° C

Relative Humidity __________________________ 5% to 95% non-condensing

Physical Case _________________________ Fully enclosed metal construction

Dimensions ____________________________________ 5.5"L x 7.5"W x 1.5"H

___________________________________ 14 cm x 19 cm x 3.8 cm

Weight _______________________________________________ 2.5 lb, 1.13 kg

Topology Solutions

Central Office/

POP

Customer Premises

SNMP Control

Radiance R5000

Remote

Status

 

 

 

Reporting

Configuration

 

 

 

 

 

Used

Communications0

 

 

 

Bandwidth

 

 

 

 

 

 

 

 

Path

 

 

Instructions

=

 

 

 

 

 

Radiance R200

Radiance R200 Premise Service Platform

9

Page 9
Image 9
METRObility Optical Systems R200 manual Platform Technical Specifications, Topology Solutions, Power, Environmental