MetroSelect

Extended Key Code Reference Table

 

Key

At Scan Code

XT/PS2 Scan Code

Prefix/Suffix Value

 

Hex = Decimal

 

 

 

 

 

F11

78H

57H

9AH = 154

 

F12

07H

58H

9BH = 155

 

Numeric +

79H

4EH

9CH = 156

 

Numeric -

7BH

4AH

9DH = 157

 

Numeric *

7CH

37H

9EH = 158

 

Caps Lock

58H

3AH

9FH = 159

 

Num Lock

77H

45H

A0H = 160

 

Left Alt

11H

38H

A1H = 161

 

Left Ctrl

14H

1DH

A2H = 162

 

Left Shift

12H

2AH

A3H = 163

 

Right Shift

59H

36H

A4H = 164

 

 

 

 

 

 

Print Screen

Multiple

 

A5H = 165

 

Tab

0DH

OFH

A6H = 166

 

Shift Tab

8DH

8FH

A7H = 167

 

Enter

5AH

1CH

A8H = 168

 

ESC

76H

01H

A9H = 169

 

Left ALT Make

11H

36H

AAH = 170

 

 

 

 

 

 

Left ALT Break

11H

B6H

ABH = 171

 

Left CTRL Make

14H

1DH

ACH = 172

 

Left CTRL Break

14H

9DH

ADH = 173

 

* Left ALT + 1 character

11H

36H

AEH = 174

 

 

 

 

 

 

* Left CRTL + 1 character

14H

1DH

AFH = 175

* Example

1st Configurable Prefix = 174 2nd Configurable Prefix = 065

Scanner will transmit <Left ALT Make> “A” <Left ALT Break>