MetroSelect

Enable “F/L” Laser Command

118014

When enabled, the scanner will turn off the laser after the scanner receives an ASCII “F” character. The laser will turn on after it receives an ASCII “L” character.

Motor On/Off Using

M/O Commands

118213

When enabled, the motor will turn on after the scanner receives an ASCII “M” character. The scanner will turn off the laser and motor after it receives an ASCII “O” character.

For use with omnidirectional scanners only.

D-19

*Disable “F/L” Laser Command

118004

Do not monitor “F/L” commands.

*Disable M/O

Commands

118203

Do not monitor M/ O commands.