MGE UPS Systems 66074, 66244, 66846 user manual Notified Applications

Models: 66074 66244 66846

1 69
Download 69 pages 410 b
Page 35
Image 35

www.mgeups.com

Network

Management Cards

User Manual

3.5.3 Notified Applications

Click the “Notified Application” section in the menu.

Security: the administrator has to enter his login/password to view this information.

This menu enables:

ZThe addition of the supervision stations receiving traps and configuration of the trap type.

ZTo list all the Notified Applications and the main parameters.

ZSimulate events to test notification and shutdown of the Notified Applications.

Up to 50 destinations can be managed by the card.

The card is compatible with the Network Shutdown Module and with the legacy SNMP UM-Client

Note: It is not necessary to add the Network Shutdown Modules protecting your servers in this list as it is done automatically.

Select an entry in the list to modify the values in the edit zone at the bottom of the page. Note that the Network Shutdown Module and the UM-Client must not be manually modified.

The applications in the table appears in the order they have subscribed to the card. Following informations are displayed :

ZNr : is the index where the application is stored into the table.

ZHostname or IP Address : By priority the hostname of the computer is displayed when the IP address can be converted into a hostname with a DNS server or if the application has been entered as a hostname (see page Network Management System settings). Otherwise the IP address is displayed.

ZApplication Name : sent by the application at subscribe time or manually entered.

ZOutput : is the number of the output from which the client is powered.

ZConfiguration : shows where the parameters of Network Shutdown Module comes from : Local(coming from the application) or Central(coming from the card).

ZThe Central Shutdown Configuration is available by clicking on Configuration link.

ZShutdown duration : is the shutdown duration necessary to properly shutdown the computer.

ZShutdown after : is the time available to the user from the Power failure until the launch of the shutoff sequence of the UPS. This parameter is optionnal.

Many actions are available on this page :

T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R

Network Management Card – User Manual

34003676EN/GA

Page 35/69

Page 35
Image 35
MGE UPS Systems 66074, 66244, 66846 user manual Notified Applications

66074, 66244, 66846 specifications

MGE UPS Systems, a renowned leader in the uninterruptible power supply (UPS) sector, offers a range of products designed to deliver reliable power protection for critical applications. Among their notable models are the MGE UPS Systems 66846, 66244, and 66074, each offering unique features, advanced technologies, and robust characteristics tailored for various operational needs.

The MGE UPS Systems 66846 is characterized by its high efficiency and modular design, making it suitable for a wide array of environments. This model incorporates advanced power management capabilities, which ensures that users benefit from enhanced energy savings while maintaining optimal performance. With a scalable architecture, the 66846 can adapt to evolving power requirements, providing users with the flexibility to expand their system as their needs grow. The model also includes intelligent battery management features that prolong battery life and enhance reliability.

Moving to the MGE UPS Systems 66244, this model stands out for its compact design and high power density. It is engineered to deliver superior electrical performance while occupying minimal space, making it an excellent choice for facilities with limited room for equipment. The 66244's advanced thermal management system ensures that the device operates efficiently under varying load conditions without overheating. Its intuitive user interface simplifies monitoring and managing the UPS, giving users real-time insights into operational status and alerts.

The MGE UPS Systems 66074 offers advanced features geared towards critical infrastructure in data centers and telecom applications. This model boasts high fault tolerance and redundancy mechanisms, ensuring continuous power delivery even in the event of component failure. The 66074 is equipped with cutting-edge digital signal processing technology, which enhances the performance and reliability of the power supply. Additionally, it supports various connectivity options, allowing for seamless integration with existing power management systems.

Across these models, MGE UPS Systems emphasize user-friendliness with intuitive control interfaces and remote monitoring capabilities. Furthermore, their commitment to sustainability is evident in the energy-efficient designs that reduce the overall carbon footprint of power management operations. Each unit is rigorously tested to adhere to international safety and performance standards, ensuring confidence in their reliability for critical applications. Overall, MGE UPS Systems 66846, 66244, and 66074 represent a blend of innovation, efficiency, and dependability in the UPS market, making them ideal choices for businesses looking to safeguard their operations against power interruptions.