SECTION 2 - INSTALLATION
B.Stacking
|
| For single ovens, skip ahead to Part C, Restraint Cable |
|
| Installation. For double or triple ovens, continue on to Step |
|
| 1, below. |
ENGLISH | 1. | Assemble the stacking spacer(s) as shown in Figure |
| One spacer assembly is supplied for a double oven, while | |
|
| |
|
| two are supplied for a triple oven. |
| 2. | Place one of the assembled spacers on top of the lower |
|
| oven cavity, making sure that the insulation faces up. |
| 3. | Place the center oven cavity (for triple ovens) or the top oven |
|
| cavity (for double ovens) on top of the spacer. Check that |
|
| all four sides of the spacer overlap the base of the oven, and |
|
| that the oven is level and firmly seated. See Figure |
| 4. | For triple ovens, repeat Steps 2 and 3 to install the top oven |
|
| cavity. |
Figure 2-6 - Stacking
Assembled
spacer
(insulation faces up)
Figure 2-5 - Assembling the stacking spacers
hex screws
Stacking panel,
P/N 44837
Top panel,
P/N 42882
C.Restraint Cable Installation
Because the oven is equipped with casters, a restraint cable assembly must be installed to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping. One end of the cable is anchored to the eyebolt on one of the rear leg extensions, while the other is anchored to the wall. See Figure
After connecting the restraint cable, move the oven to its final location. Then, lock the two front casters.
Figure 2-7 - Installing the Restraint Cable
Restraint cable
assembly
3/4” (19mm)
eyebolt
Wall of
structure
10