Miele CS 1112, CS 1122 Installation, Safety distance from the wall covering

Models: CS 1112 CS 1122

1 40
Download 40 pages 6.46 Kb
Page 27
Image 27
Installation

Installation

Safety distance from the wall covering

If a wall covering is installed, a minimum safety distance must be maintained between the countertop cut-out and the covering, since high temperatures can damage these materials.

If the covering is made of a combustible material (such as wood), the distance between the countertop cut-out and the wall covering must be a minimum of 2" (50 mm).

For coverings made of non-combustible materials (such as metal, marble, granite or ceramic tiles) the minimum safety distance e between the countertop cut-out and the wall covering must be 2" (50 mm) minus the thickness of the covering. For example: thickness of wall covering 9/16" (15 mm)

2" (50 mm) - 9/16" (15 mm) = minimum safety distance 1 3/8" (35 mm).

aWall frame

bWall covering

x = thickness of the wall covering

cCountertop

dCountertop cut-out

eMinimum safety distance

with flammable materials 2" (50 mm)

with non-flammable materials 2" (50 mm) minus x

27

Page 27
Image 27
Miele CS 1112, CS 1122 installation instructions Installation, Safety distance from the wall covering