Safety distances to the sides of the appliance

SAFETY INSTRUCTIONS FOR INSTALLATION

Safety distances to the sides of the appliance

The appliance should only be installed as shown in the illustrations, while maintaining the required safety distances shown. Do not install the appliance between two tall cabinets, this is a fire hazard.

A distance of at least 2" (50 mm) must be kept between the countertop cut-out and the rear wall because of the high temperatures radiated.

The minimum distance a between the worktop cut-out and a wall or tall unit to the right or left of it is:

2" (50 mm)

for

CS 1112

 

 

CS 1122

 

 

CS 1212

 

 

CS 1221

 

 

CS 1223

 

 

CS 1326

 

 

CS 1411

6" (150 mm)

for

CS 1312

 

 

CS 1322

 

 

CS 1421

10" (250 mm) for

CS 1011

 

 

CS 1012

 

 

CS 1028

2 " (50 mm)

recommended

2" (50mm)2" (50 mm)

1

not recommended

not permitted