Miele DA279-3 installation instructions Condensate trap, Air extraction

Models: DA279-3

1 36
Download 36 pages 61.64 Kb
Page 34
Image 34
Condensate trap

Air extraction

If the exhaust is ducted into an inac- tive flue, the air must be expelled parallel to the flow direction of the flue.

Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connect- ing an exhaust hood vent to an exist- ing, inactive chimney or vent flue.

Condensate trap

Important:

If the ductwork runs through rooms, ceilings, garages, etc. where tempera- ture variations exist, it may need to be insulated to reduce condensation. In some cases, a condensate trap may also be required to collect and evapo- rate any condensate which may occur.

When installing a condensate trap, ensure that it is positioned vertically and if possible directly above the exhaust outlet.