Miele DA2900 Operation with Control module DSM, Potential free connection, Installation

Models: DA2900EXT DA2900

1 40
Download 40 pages 60.88 Kb
Page 34
Image 34
Operation with Control module DSM 400

Operation with Control module DSM 400

The Miele DSM 400 control module (optional accessory) can be used to combine the cooker hood with other components.

It enables the following:

Potential free connection

This can be used to operate a further appliance via the On/Off button ￿ of the cooker hood.

The potential free contact on the

DSM 400 ￿ can, for example, be used in a cooker hood with an external motor

...EXT, which is connected to a central ducting system.

The contact can then be used to operate an electrically driven non-return flap ￿ which is connected to the central extraction unit ￿.

Components used in the central ducting system are not supplied by Miele.

If in any doubt, the advice of a competent builder or, for gas, a Gas Safe installer must be sought.

Connection to a push button switch

The control module can be used to switch on the cooker hood lighting via a push button switch in the house.

Installation

The control module is fitted onto the cooker hood housing.

The electrical connection of components to the control module must be carried out by a suitably qualified and competent person.

34

Page 34
Image 34
Miele DA2900EXT Operation with Control module DSM, Potential free connection, Connection to a push button switch