Installation
Lift the cooker hood into the unit from below until the lugs of the brackets lie above the support tracks. Then carefully lower the cooker hood. The lugs engage with the support track.
To align the height, turn the
M 6 x 19 mm adjuster screws clock- wise or
Move the cooker hood into its correct position.
Feed the air extraction or air
Replace the dividing wall in the wall unit.
Pull the deflector plate out to its limit and remove the grease filters.
4 holes (DA 262 i / DA 272 i) or
6 holes (DA 292 i) are now visible.
Use a sharp pointed instrument through these holes to gouge out the fixing holes.
Then screw the cooker hood se- curely to underside of wall unit.
Replace the grease filters.
Depth alignment
Units deeper than 285 mm require the fitting of a spacer bar to prevent va- pours collecting between the rear of the cooker hood and the wall.
Secure the cooker hood on both sides using four 3 x 16 mm
( 5/8 ")screws for each side.
2 1
1
To achieve the correct depth shorten the . . .
. . . spacer bar at the required break- ing points.
. . . End caps.
Fit the end caps (1) to both ends of the spacer bar.
18