Appliance dimensions
Exhaust air ducting using the DAG 500 internal blower, installed on the front of the appliance [vent duct 6"
(150 mm)]: to the left or right, downwards, to the rear.
If the blower is being installed at the rear of the appliance, a
Feed the power cord and control cable when using an external blower downwards or to the rear.
Using the DAG 1000 external blower, install exhaust ducting to the rear (vent duct 10" (254 mm)).
If installing the exhaust ducting to the front, appropriate clearances must be maintained in the cabinet.
a)Cooktop overhang
b)Minimum width of the cooktop: DA 6480: 28" (711 mm)
DA 6490: 34" (864 mm)
–The specified dimensions minimum
–If an oven or stove is installed before the ventilation system, read the associated installation instructions. Note all installation dimensions and guidelines regarding ventilation systems.
–Be aware of kitchen cabinets, back splashes and/or racks in the area of the ventilation system and the cooktop. Ensure that the area where the vent rises is free of obstacles.
–Make sure that any required minimum distance between the front edge of the countertop and the front edge of the cooktop is maintained.
–If there is a drawer in the way, it must be shortened or removed. The front panel of the drawer could also be installed to permanently cover the drawer
23