Electrical connection if using an external blower

Electrical connection

Electrical connection if using an external blower

If using the external blower, install a connection cable between the ventilation system and the external blower.

Please follow the Operating and Installation Instructions for the DAG 1000.

￿Connect to the power supply as described previously.

￿The external blower will be connected to the additional control cable.

￿Close the terminal box.

￿Turn the power supply back on.

Maximum load

with interior-mounted

DAG 500 vent motor . . . . . . . . . . 420 W

with exterior-mounted

DAG 1000 vent motor . . . . . . . . . 210 W

Voltage . . . . . . . . . . . . . . . . . . . . . 120 V

Frequency . . . . . . . . . . . . . . . . . . 60 Hz

Circuit Rating . . . . . . . . . . . . . . . . . 15 A

￿Additional housing knock-outs should be used for the external blower housing.

￿Install a suitable UL listed cable clamp or conduit fitting into the knock-out.