Electrical connection

Electrical connection - CDN

The extractor is supplied with a 1.10 m power supply cable ready for connec- tion to a 120 VAC, 60 Hz supply.

The rated load is 110 W. Fuse rating is 10 A.

Caution:

Make sure the power supply is OFF during installation.

Important

The wires of the power cord are co- lored as follows:

Green = ground

Black = live

White = neutral

WARNING

THIS APPLIANCE MUST BE GROUNDED

Electrical connection - USA

The extractor is supplied with a 4 ft cord ready for connection to a

120 VAC, 60 Hz power supply. Connec- tion should be made in an appropriate junction box.

The rated load is 110 W. Fuse rating is 10 A.

Important

The wires of the power cord are color- coded as follows:

Green/Yellow = ground

Blue = neutral

Brown = live

As the colors of the wires in the power supply cord of this appliance may not correspond with the colors of the wires in your junction box, proceed as follows:

The green and yellow wire must be con- nected to the ground wire.

The blue wire must be connected to the neutral wire.

The brown wire must be connected to the hot wire.

WARNING

THIS APPLIANCE MUST BE

GROUNDED

12

Page 12
Image 12
Miele DA 8-2 manual Electrical connection CDN, Electrical connection USA