Installation instructions

Do not install the DA 8-2 directly next to a gas hob.

This extractor is designed for installa- tion between Combiset appliances. It should always be installed between two appliances, such as the grill and deep fryer.

23/16˝

 

 

 

 

19

5

/16˝

 

 

 

 

 

 

 

2

3

/16˝

 

 

 

Prepare the countertop cut-out as il- lustrated.

Dimension ”B“ will vary depending on how many combisets are in- stalled. The following chart gives dimension ”B“ for a variety of 2 zone (ie KM 88-2) and 4 zone (ie KM 93-2) combinations.

 

Depth

Width

 

(in

(= Dimen-

 

mm)

sion B)

 

 

(in mm)

 

 

 

2 zone Combiset

 

 

1 combiset

490

265

2 combisets

490

558

3 combisets

490

851

4 combisets

490

1144

5 combisets

490

1437

 

 

 

4 zone Combiset

 

 

1 combisets

490

560

2 combisets

490

1143

3 combisets

490

1728

 

 

 

Combination

 

 

One 2 zone

 

 

+ one 4 zone

490

851

Two 2 zone

 

 

+ one 4 zone

490

1143

Three 2 zone

 

 

+ one 4 zone

490

1437

One 2 zone

 

 

+ two 4 zone

490

1436

Two 2 zone

 

 

+ two 4 zone

490

1729

 

 

 

Extractor (e.g. DA 8-2)

For installation between two appliances: - Dimension B increases by 90 mm.

For installation at the end of a combination: - Dimension B increases by 98 mm.