Exhaust connection

Exhaust connection

Please read the ”Warning and Safety Instructions“ to avoid the danger of toxic fumes.

The DA-8 extractor should be in- stalled in accordance with local and national building regulations.

The exhaust connection should be made into a vent shaft or chimney that is not in use, using non-flammable ex- haust ducting to the outside by using a wall vent kit. These kits are available from the Miele Parts Department.

Installation should only be per- formed out by a suitably qualified and trained person.

The exhaust ducting should be as short and straight as possible.

The use of angled pipes should be avoided, as this will reduce the air flow of the extractor.

Only use ducting made of non- flammable material.

The exhaust ducting may be angled either to the left, right or downwards.

If the ducting is run beneath the cabinets it requires a toe kick height of at least 5-15/16 ’’.

If the ducting is run horizontally, en- sure that there is a gradient of at least 1/8 ’’ per foot, so that condensa- tion will not run into the appliance.