DOS 3 (neutralizer)
Setting the neutralizer dosage
Set dosage concentration according to the neutralizer manufacturer's
recommendations.
Step Display / Result
^Press the "Drying" 0button until E02
appears in the display.
E02
^Turn the program selector to "Intensive". The programmed dosage
concentration appears in the
display, e.g., 0.10 = 0.10 %
^Press and hold the "Display" ßbutton
until the required value appears in the
display, e.g., 0.2.
0.20 The dosage concentration is
now set.
Dosage concentration setting:
Priming the dosage system
The dosage system does not need to be primed (cleared of air) unless:
– the dosage concentration is being set for the first time,
– the neutralizer container was inadvertently completely emptied .
Step Display / Result
^Press the "Drying" 0button until E02
appears in the display.
E02
^Turn the program selector to "Universal". d§3
^Press the "Display" ßbutton. The dosage system will be primed
automatically. Priming is complete
when 0appears in the display.
^Exit the programming mode.
Start "Rinse" program.
This will rinse away any agents that
entered the wash cabinet during
priming.
Programming functions
36