The machine is equipped with an
interface socket so that data can be
transferred from Novotronic to a log
printer.
Please contact Miele Technical Service
to order printer cables.
The serial interface is RS 232
compatible.
Various printer types with
Epson-compatible fonts can be used
for printing.
Miele Technical Service maintains a list
of recommended printers.
Pin assignment 9-pin sub-D connector:
5 GND (ground)
3 TXD (send)
1-4-6 (bridge)
7-8 (CTS)
,Printer initialization must only be
performed by Miele. Consult
Technical Service using the contact
information on that back of this
manual.
During program operation a protocol is
prepared. It can be printed using an
external printer.
The protocol contains the following
information:
date and device number
program start time and name
rinse blocks used
dosage system with dosage
temperature and target dosage
amount
target values for temperature and
holding times
minimal temperature during the
holding time
all errors (e.g., water supply defect)
program end time
warnings, e.g., salt required.
Data transfer (optional)
43