Aligning the appliance

Installation

Aligning the appliance

^Align the appliance with the custom front.

The installation aids e have been designed for the following total thickness of custom doors:

3/4" (19 mm)

1 1/2" (38 mm).

Be sure to take into account the possible differing thicknesses of the custom doors that are to be fitted subsequently.

The height-adjustable feet at the front and rear can all be adjusted from the front.

Front: with an open-ended wrench ½" (SW 13).

The feet can be adjusted from the top and bottom f.

Rear: with a 5/16" (8 mm) hex nut driver via flexible shaft g.

A mark is located on the appliance base and is used as a standard gauge for height adjustment. When adjusting the height, align this mark at 1 1/4"

(32 mm) above the floor.

^Place a marking-out level over the installation aids e on the door.

^Unscrew the height-adjustable feet until the mark on the base has

reached the indicated guide dimension 1 1/4" (32 mm).

It is very important to comply with this dimension for the subsequent alignment of the custom door fronts.

^ Align the custom doors with a level.