Electrical connection

Electrical connection AUS / NZ

All electrical work should be carried out by a suitably qualified and competent person in strict accordance with na- tional and local safety regulations.

The appliance is supplied with a cable and moulded plug ready for connection to a 230-240 V/50 Hz a.c. single phase supply.

The voltage, rated load and fusing are given on the data plate which is located externally on the rear wall of the appli- ance. Please ensure that these match the household mains supply.

Connection should be made via a suit- able isolator, which should be easily ac- cessible after the appliance has been installed.

For extra safety it is advisable to install a residual current device with a trip cur- rent of 30 mA.

AUS / NZ

The plug rating is 15 A.

Test marks

Electrical safety

 

C-Tick Mark

Electrically suppressed

according to

AS/NZS 1044

Important

The wires in the mains lead of this ap- pliance are coloured in accordance with the following code:

Green/yellow = Earth

Blue = Neutral

Brown = Live

As the colours of the wires in the mains lead of this appliance may not corre- spond with the markings identifying the terminals in your plug, proceed as fol- lows:

The wire coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol z or coloured green or green and yellow.

The wire coloured blue must be con- nected to the terminal marked with the letter "N" or coloured black. The wire coloured brown must be connected to the terminal marked with the letter "A" or coloured red.

WARNING

THIS APPLIANCE MUST BE

EARTHED