Miele T 4422 C Problem Possible cause Remedy Condenser unit, Service panel will, Not shut

Models: T 4422 C

1 48
Download 48 pages 14.98 Kb
Page 30
Image 30

Problem solving guide

Problem

Possible cause

Remedy

The condenser unit

The inner cover of the

– Ensure that the condenser

service panel will

condenser unit has not

unit is positioned correctly

not shut.

been locked properly

and lock the cover.

 

and/or the condenser unit

– Check the rubber seals.

 

has not been positioned

 

 

correctly.

 

Water leaks from the

Fluff has collected at the

– Use a cloth to remove any

machine after the

bottom of the condenser

fluff from the inside of the

condenser unit has

unit housing.

condenser unit housing.

been cleaned.

 

 

The interior drum

The lighting switched off

The lighting only comes on

lighting does not

automatically.

when the door is opened if

come on.

 

the dryer is switched on. To

 

 

save energy the lighting

 

 

goes out after a while if the

 

 

door is left open.

 

The lamp needs changing.

Change the lamp as

 

 

described at the end of this

 

 

section.

The ring around the

The lighting switched off

It lights up when drying is in

programme selector

automatically.

progress and goes out

does not light up.

 

shortly after the end of the

 

 

programme to save energy.

Check and fault indicator lamps

 

 

 

 

Problem

Possible cause

Remedy

The Anti-crease /

The programme selector

Turn the selector back to the

Finish indicator

was moved after the start

original position and the

lamp flashes while

of a programme. The

indicator lamp will go out.

drying is in

programme continues to

 

progress.

run as normal.

 

The Locked

The system lock is

If you wish to use the dryer,

indicator lamp

activated.

the system lock must be

flashes when the

 

deactivated (see "Electronic

machine is switched

 

system lock").

on and the

 

 

programme cannot

 

 

be started.

 

 