Plumbing

Connect the cold water supply hose (hose marked blue) to the cold water valve and the hot water supply hose (hose marked red) to the hot water valve.

Turn on the valves and check for leaks. The water pressure must be within 15-145 psi (1-10 bar). If the water pressure is greater than 145 psi

(10 bar), a pressure reducer must be in- stalled. If the water pressure is below

15 psi (1 bar), insufficient water may be available for a complete fill.

The water supply hoses are equipped with filters; please do not remove these filters.

Special note

If connecting the machine to a cold water supply only, use the included Y- adapter to connect both hoses to the cold water valve, otherwise the cor- rect functioning of the machine could be impaired. The machine should not be connected to hot water only.

Connection to the drain sys- tem

The 5 ft. (1.5 m) drain hose may be con- nected as follows:

1.Directly into a sink: hook the hose over the edge of the sink and secure it firmly (e.g. by tying the hose to the water faucet).

2.Connection to a stand pipe: place the drain hose into a 1 1/2" (38 mm) stand pipe and firmly secure it. (An anti-siphoning device is not required as there is one built into the ma- chine.)

3.To a floor drain: if desired, the drain hose may be extended to 15 ft. (4.5 m) maximum.

The machine drains using a pump with a maximum delivery height of 4 ft.

(1.2 m).

Make sure there are no kinks in the drain hose.

The machine is equipped with an air- gap/anti-siphoning system so that no minimum drain height is required.

40

Page 40
Image 40
Miele W 1930I operating instructions Plumbing, Connection to the drain sys- tem