Milan Technology T1E1-CF-01(SM) instruction manual Compliance Information, T1/E1 Copper-to-Fiber

Models: T1E1-CF-01(SM) T1E1-CF-01(SE)

1 6
Download 6 pages 15.84 Kb
Page 1
Image 1
COMPLIANCE INFORMATION

COMPLIANCE INFORMATION

UL Listed

C-UL Listed (Canada)

CISPR/EN55022 Class A

FCC Regulations

This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.

Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

T1/E1 Copper-to-Fiber

Media Converters

T1E1-CF-01

USER’S GUIDE

TRANSITION Networks T1E1-CF-01 series media converters encode and decode T1 OR E1 signals over duplex fiber cables to extend the distance and transmission reliability of high speed T1 and E1 data traffic.

European Regulations

Warning

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Achtung !

Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.

Attention !

T1E1-CF-01

Provides an RJ-45 twisted pair connector for T1 OR E1 signals, a set of RX (receive) and TX (transmit) coax connectors for E1 signals, and a set of RX and TX ST connectors to 850 nm multimode fiber-optic cable.

T1E1-CF-01(SM)

Provides an RJ-45 twisted pair connector for T1 OR E1 signals, a set of RX (receive) and TX (transmit) coax connectors for E1 signals, and a set of RX and TX ST connectors to 1300 nm singlemode fiber-optic cable.

Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées

CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.

Trademark Notice

All registered trademarks and trademarks are the property of their respective owners.

Copyright Restrictions

© 1999-2001 TRANSITION Networks.

All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.

Printed in the U.S.A.

33112.E

T1E1-CF-01(SC)

Provides an RJ-45 twisted pair connector for T1 OR E1 signals, a set of RX (receive) and TX (transmit) coax connectors for E1 signals, and a set of RX and TX SC connectors to 850 nm multimode fiber-optic cable.

T1E1-CF-01(LH)

Provides an RJ-45 twisted pair connector for T1 OR E1 signals, a set of RX (receive) and TX (transmit) coax connectors for E1 signals, and a set of RX and TX ST connectors to 1300 nm singlemode fiber-optic cable.

T1E1-CF-01 in the Network . .

. . . . .2

Installation

. . . . .4

Operation

. . . . .7

Fault Isolation and Correction

. . . . .8

Cable Specifications

. . . .10

Technical Specifications

. . . .11

Compliance Information

. . . .12

Page 1
Image 1
Milan Technology T1E1-CF-01(SM) instruction manual Compliance Information, T1/E1 Copper-to-Fiber, User’S Guide