CABLE SPECIFICATIONS

CABLE SPECIFICATIONS

Fiber Cable

Bit error rate:

10-9

 

MULTIMODE

 

 

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

 

85 / 125 µm multimode fiber

 

50 / 125 µm multimode fiber

T1E1-CF-01

850 nM

 

Fiber Optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber Optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical Maximum Cable Distance*:

2 kilometers

 

T1E1-CF-01(SC)

850 nM

 

Fiber-optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical Maximum Cable Distance*:

2 kilometers

 

SINGLEMODE

 

 

Fiber Optic Cable Recommended:

9 µm singlemode fiber

T1E1-CF-01(SM)

1300 nM

 

Fiber-optic Transmitter Power:

min: -21.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Typical Maximum Cable Distance*:

8 kilometers

 

T1E1-CF-01(LH)

1300 nM

 

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Typical Maximum Cable Distance*:

15 kilometers

 

*Actual distance dependent upon physical characteristics of network installation.

Twisted-Pair Copper Cable

Twisted pair connection requires two active pairs. The two active pairs in a T1/E1 network are pins 1 & 2 and pins 4 & 5. Use only dedicated wire pairs (such as blue/white & white/blue) for the active pins.

Category 3 or better twisted-pair copper wire is required. Either shielded twisted- pair (STP) or unshielded twisted-pair (UTP) can be used.

T1:

Gauge

24 to 22 AWG

Attenuation

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

100 ±10%

E1:

Gauge

24 to 22 AWG

Attenuation

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

120 ±10%

Coax Copper Cable

 

E1:

 

Gauge

24 to 22 AWG

Attenuation

2 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

75 ±10%

å

Dry-Contact Relay

RJ-45 dry-contact relay opens if power, signal detect/copper or signal detect/fiber are lost.

Relay

3RJ-45

6

Operational rating on pins 3 and 6: 0-30VDC maximum 1A

Switch-Selectable Configurations

T1 COPPER RJ-45

Configured as either "long haul" or “short haul” on 100 ohm cable, with a variety of selectable distance settings.

E1 COPPER RJ-45

Configured as either "long haul" or “short haul” on 120 ohm cable.

E1 COPPER COAX

Configured as either "long haul" or “short haul” on 75 ohm cable.

STRAIGHT-THROUGH/CROSSOVER RJ-45

Allows straight-through cable to be used where crossover-configuration cable is required.

Switch-Selectable Functions

LOOPBACK TEST FUNCTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TP

 

 

 

 

Fiber

 

 

 

 

 

 

 

 

TP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A loopback switch facilitates installation and network debug procedures. The path for the T1E1-CF-01 loopback is shown:

TRANSMIT ALL ONES FUNCTION

A selectable Transmit All Ones switch on the fiber interface and on the twisted-pair interface allows for insertion of an “all ones” pattern on that interface when signal detect is lost, which creates an alarm condition at the equipment connected to the interface.