Milan Technology T1E1-CF-01(SE) T1E1-CF-01 IN THE NETWORK, Features, Technical Specifications

Models: T1E1-CF-01(SM) T1E1-CF-01(SE)

1 6
Download 6 pages 15.84 Kb
Page 2
Image 2
T1E1-CF-01 IN THE NETWORK

T1E1-CF-01 IN THE NETWORK

TECHNICAL SPECIFICATIONS

NOTE: THE T1E1-CF-01 REQUIRES A CSU BETWEEN THE MEDIA CONVERTER AND THE PUBLIC TELEPHONE NETWORK.

OR

E1

T1 OR E1

T1 or E1

 

Network Extension

 

 

 

UTP/STP

Fiber

Standards

Emissions: CISPR A

 

 

T1/E1 Physical Layer: ITU-T, ANSI, AT&T, ETSI

Case Dimensions

4.75" x 3.0" x 2.0"

(119mm x 76mm x 50mm)

Shipping Weight

3 pounds

(1.4 kilograms)

Delay

400nsec round trip

 

Environment

Temperature:

0-50°C (32° to 122° F )

 

Humidity

10-90%, non condensing

 

Altitude

0-10,000 feet

Power Supply Requirements Replace power supply with only the equivalent input rating (see below) and output rating (unregulated 9 VDC).

T1 or E1

E1

TN PNRequirementLocation

3507

240 volts, 50 hertz

United Kingdom

3342

230 volts, 50 hertz

Europe

3340

120 volts, 60 hertz

USA/Canada/Mexico

3346

100 volts, 50-60 hertz

Japan

3511

240 volts, 50 hertz

Australia

3537

(with power cord: 3522)

South Africa

NOTE: This product also can be powered by the Transition Networks E-MCR series media converter rack.

WarrantyLifetime

E1

OR

CSU

T1 or E1

T1 or E1

OR

To Telco

To Telco

 

 

 

DECLARATION OF CONFORMITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name of Mfg:

Transition Networks

 

 

6475 City West Parkway, Minneapolis MN 55344 USA

Model:T1E1-CF-01 Series Copper-to-Fiber Media Converter

Part Number: T1E1-CF-01, T1E1-CF-01(SC), T1E1-CF-01(SM),

Features

Media converter is framing independent (as ESF vs D4) and supports all common line codes, (AMI, B8ZS, HDB3).

Distance extensions of 2 km 850 nm multimode or 8 km 1300 nm singlemode.

Jitter attenuators optimize Bit Error Rate (BER) performance.

Dry relay contacts allow media converter to be tied into separate alarm circuit

All Ones Insertion (AIS), indicated by LEDs, on loss of signal at copper and/or fiber interface.

T1E1-CF-01(LH)

Regulation: EMC Directive 89/336/EEC

Purpose: To declare that the T1E1-CF-01and T1E1-CF-01(SM)to which this declaration refers is in conformity with the following standards.

EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992; EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).

 

 

 

_June 8, 1999_____

 

Stephen Anderson, Vice-President of Engineering

Date

 

 

 

 

Page 2
Image 2
Milan Technology T1E1-CF-01(SE) T1E1-CF-01 IN THE NETWORK, Features, Technical Specifications, T1 OR E1, Network Extension