Milan Technology T1E1-CF-01(SM), T1E1-CF-01(LH) FAULT ISOLATION and CORRECTION, Proceed to step

Models: T1E1-CF-01(SM) T1E1-CF-01(SE)

1 6
Download 6 pages 15.84 Kb
Page 5
Image 5
FAULT ISOLATION and CORRECTION

FAULT ISOLATION and CORRECTION

If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:

1.

Is the Power LED on the media converter illuminated?

 

NO

 

• Is the power adapter the proper voltage and cycle frequency for the

 

AC outlet?

 

NOTE: Refer to the “Power Supply Requirements” on page 7.

 

• Is the power adapter properly installed in the media converter and

Set switches 5, 6, and 7 to enable test functions or to permit normal network operation. (Switch 8 not used.)

1

2

3

4

5

6

 

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*NETWORK Switch Settings

5 6 7 8

 

 

in the outlet?

 

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

 

YES

 

 

Proceed to step 2.

2.

Is the SDFiber (Signal Detect/Fiber) LED illuminated?

 

NO

 

 

Check fiber cables for proper connection.

 

Verify that TX and RX cables on media converter are connected to

 

 

RX and TX ports, respectively, on other media converter.

 

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

 

YES

 

 

Proceed to step 3.

3.

Is the SDTP (Signal Detect/Twisted-Pair) LED illuminated?

 

NO

 

 

Check twisted pair cables for proper connection.

 

Check RJ-45 Pinning Switch for correct twisted pair cable

 

 

configuration.

 

Check integrity of device attached to media converter by twisted-

 

 

pair cable.

KEY

 

1

2

= UP

 

= DOWN

 

1

2

1

2

1

2

1

2

12

Normal Operation

Loop Transmit TP to Receive TP

Transmit All Ones onto Fiber on loss of SDFiber

NO Transmit All Ones onto Fiber

Transmit All Ones onto TP on loss of SDTP

NO Transmit All Ones onto Twisted-Pair

 

• Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

 

YES

 

• Proceed to step 4.

4.

Is the AISFiber LED on either media converter illuminated?

 

NO

 

• Proceed to step 5.

YES

*Switch #8 not used.

Set the MDI/MDI-X switch to use straight-through cable where crossover- configuration cable is required.

Determine if broken fiber link has caused All Ones Insertion (AIS) on the fiber interface and correct failure. If not, proceed to step 5.

MDI

MDI-X

TP

AISFiber

Fiber

TP

Twisted Pair #1

Twisted Pair #2

1

RTIP

 

TTIP

Twisted

 

2

RRING

 

TRING

Pair

#1

 

4

TTIP

 

RTIP

Twisted

 

5

TRING

 

RRING

Pair

#2

 

Connectors for unlike devices

1

RTIP

 

 

 

RTIP

 

 

2

RRING

 

 

 

RRING

 

 

4

TTIP

 

 

 

TTIP

 

 

5

TRING

 

 

 

TRING

 

 

Connectors for like devices

Page 5
Image 5
Milan Technology T1E1-CF-01(SM), T1E1-CF-01(LH), T1E1-CF-01(SE) FAULT ISOLATION and CORRECTION, Proceed to step