INSTALLATION (continued)

INSTALLATION (continued)

Install Cable

COPPER

OPERATION

After installation, the media converter should function without operator intervention.

T1 100 OHM (RJ-45 CONNECTOR)

OR E1 120 OHM (RJ-45 CONNECTOR)

NOTE: KEEP TWISTED-PAIR RUNS AS SHORT AS POSSIBLE.

Locate or build twisted-pair cables that are compliant with specifications on page 10.

Connect male RJ-45 plug connector at one end of cable to media converter RJ-45 jack connector.

Set MDI/MDI-X switch to MDI-X according to network conditions.

Connect male RJ-45 plug connector at other end of cable to network equipment..

E1 75 OHM (COAX CONNECTOR)

Status LEDs

Use the status LEDs to monitor media converter operation in the network.

Power

Steady green

 

LED indicates

 

connection to

 

external AC

 

power.

SDFiber

Signal

 

Detect/Fiber -

 

Steady green

 

LED indicates

 

fiber link is up.

Power Install Cable

SDFiber OPERATION

AISFiber T1 100 OHM (RJ-45 CONNECTOR)

E1 75 OHM (COAX CONNECTOR)Coax

Status LEDs SDTP Power AISTP

NOTE: Ground coax segment to earth ground at one end.

Locate or build coax cables that are compliant with specifications on page 10.

Connect BNC connector at one end of cable to media converter.

Connect BNC connector at other end of cable to network equipment..

FIBER

Locate or build duplex fiber cables that are compliant with specifications on page 10.

Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on media converter.

Connect male TX and RX cable connectors at other end of cable to RX and TX connectors of compliant fiber device.

Connect to Power

Install Power Adapter cord at back of Media Converter.

Connect Power Adapter plug to AC power.

Verify that Media Converter is powered by observing illuminated LED(s).

AISFiber

All Ones Insertion/Fiber - Blinking green LED indicates all ones

 

received on fiber

Coax

Steady green LED indicates coax interface selected.

SDTP

Signal Detect/Twisted-Pair- Steady green LED indicates

 

twisted-pair link is up.

AISTP

All Ones Insertion/Twisted-Pair - Blinking green LED indicates

 

all ones received on twisted-pair

Page 6
Image 6
Milan Technology T1E1-CF-01(SE) INSTALLATION continued, Operation, Install Cable, Status LEDs, Connect to Power, SDFiber