7-5. Checking Or Replacing Filter Element

6

5

4

3

1

2

1Latch

2Filter Cup

3Retaining Nut

4Filter Element

5Defuser Ring

6Filter Cap

Slide latch down, and rotate filter cup approximately 1/4 turn.

Remove cup.

Remove retaining nut, filter element, and defuser ring.

Check filter element for dirt and moisture, and replace if necessary.

Be sure that all parts are clean and dry.

Reinstall all parts, and secure filter cup.

804 054-A

OM-201 872 Page 41