4-3. Fuses F1 And F2
2
1
Tools Needed:
3/8 in
YTurn Off unit, and disconnect input power.
1Fuse F1 (See Parts List For Rating)
F1 protects the 115 volts ac winding of transformer T1. If F1 opens, all weld output stops and pilot light PL1 goes out.
2Fuse F2 (See Parts List For Rating)
F2 protects the 24 volts ac winding of transformer T1. If F2 opens, all weld output stops.
Ref.
4-4. Changing Drive Roll And Wire Inlet Guide
5
1 Securing Screw
3
2 Inlet Wire Guide
Loosen screw. Slide tip as close to
2drive rolls as possible without touching. Tighten screw.
3
Install guide as shown.
4 Drive Roll
Install correct drive roll for wire size and type.
| 1 | 5 Drive Roll Securing Nut |
|
| |
Tools Needed: |
| Turn nut one click to secure drive |
| roll. | |
|
| |
5/64 in | 4 |
|
|
| |
7/16 in |
|
|
|
|
4-5. Replacing Gun Contact Tip
Y Turn Off unit before replacing contact tip.
1 Nozzle
2 Contact Tip
Cut off welding wire at contact tip.
Remove nozzle.
2
Remove contact tip and install new
contact tip. Reinstall nozzle.
1
Tools Needed:
Ref. 800