5-9. Process Set Up Push Button
3
Process |
Wire Type |
Gas Type |
2 |
1 |
Process Set Up |
1Process Set Up Push Button
2Process Set Up LED
3Program Selection LEDs
•Press the Process Set Up push button the first time will illuminate the button LED and Process LED above the button. Both displays will show the current process and, if desired, these displays will be active to allow selecting a new process. Default processes are MIG, PULSE, and ACCU PULSE.
•Pressing the Process Set Up push button a second time will illuminate the Wire Type LED and the bottom display will show wire types available for the selected process. To make a selection, rotate the Adjust control.
•Pressing the Process Set Up push button a third time will keep Wire Type LED lit, but the upper display will be active and show wire sizes available for the current wire type. To
make a selection, rotate the Adjust control.
•Pressing the Process Set Up push button a fourth time will illuminate the Gas Type LED and both displays will show available gas selections for the process, and wire type and wire size selection. To select an item, rotate the Adjust control.
•Pressing the Process Set Up push button a fifth time will load the program that matches the selected parameters (process, wire type, wire size, gas). The upper display will show PROG and the lower display will show LOAD.
If no changes were made to any setup items, no program will be loaded, and unit will return to standby mode.
If a custom program is loaded using an optional PDA with File Management software, the upper display will show CUST and the lower display will show PROG. The Adjust control remains active to allow loading a standard program in place of the custom program.
•Pressing and holding the Process Set Up push button in on power up allows viewing the software revisions of each circuit board in the system. The top display shows the board (PCM, UIM, WFCM, and AIM (auto- mated units only) and the lower display shows the last 3 digits of the circuit board part number plus a letter designator. Press the flashing Feeder Set Up push button to exit the screen displays and continue the power up process.
Table
Wire Description | Wire Abbreviation | Alloy Type | Gas Type | Gas Abbreviation |
|
|
|
|
|
Steel | STL | E70, E100, E120 | 100% CO2, | CO2 |
|
|
| 90% Argon/10% CO2, | C10 |
|
|
| 85% Argon/15% CO2, | C15 |
|
|
| 75% Argon/25% CO2, | C25 |
|
|
| 95% Argon/5% CO2, | C5 |
|
|
| 95% Argon /5% O2, | OX5 |
|
|
| 98% Argon/2% O2 | OX2 |
Stainless Steel | SS | 308, 309, 312, 316 | 98% Argon, 2% O2 | OX2 |
|
|
| (81Ar/18HE/1CO2 | Tri Gas |
|
|
|
| |
|
|
| Tri Gas | |
|
|
|
| |
|
|
|
|
|
Cored Tubular Wire | MCOR | 71, 76, 86R, 409, | 90% Argon/10% CO2 | C10 |
|
| 439 |
|
|
|
| 98% Argon/2% O2 | OX2 | |
|
|
| ||
Aluminum | ALUM | 4XXX, 5XXX | 100% Argon | ARGN |
|
|
|
|
|
* Not all wire types may be available with your unit. |
|
| ||
|
|
|
|
|