Lens Delay Control

The lens delay control is used to slow the lens-switching time to the clear state after welding. The delay is particularly useful in eliminating bright after-rays present in higher amperage applications where the molten puddle re- mains bright momentarily after welding. Adjusts from 0.10 second (Min) to 1.0 sec- ond (Max).

Low Battery Indicator

The low battery indicator lights when 2−3 days of battery life remain.

Replace the battery with a readily available coin type CR2450 Lithium Battery or equivalent. (Miller Part No. 217043) (see Section 4).