SECTION 2 – INSTALLATION

2-1. Specifications

Rated Welding

Voltage Range

Maximum Open-

Amperes Input at Rated Load

 

 

Output, 60 Hz, Single-Phase

 

 

Output

DC

Circuit Voltage DC

 

 

 

 

 

200 V

230 V

460 V

KVA

KW

 

 

 

 

 

 

 

 

 

 

 

200 A @ 28 Volts DC,

Low Range: 10–20

 

46

40

20

9.2

8.3

V; High Range:

42

60% Duty Cycle

(1.2*)

(1.0*)

(0.5*)

(0.2*)

(0.1*)

20–30 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating.

If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or voltage, or duty cycle before welding.

Y Exceeding duty cycle can damage unit and void war- ranty.

60% Duty Cycle At 200 Amperes

6 Minutes Welding

4 Minutes Resting

Overheating

0

A or V

 

15

 

OR

Minutes

Reduce Duty Cycle

 

sduty1 5/95 / 155 647-A

OM-293 Page 9