SECTION 4 – MAINTENANCE & TROUBLESHOOTING

4-1.

Routine Maintenance

 

 

 

 

 

Y Disconnect power before maintaining.

 

 

 

 

 

3 Months

 

 

 

 

Replace

 

 

Repair Or

 

 

 

Replace

 

Unreadable

 

 

 

 

 

Cracked

 

Labels

 

 

 

 

 

 

Weld

 

 

 

 

 

 

 

 

 

 

Cable

 

Clean And

 

 

 

Replace

 

Tighten

 

 

 

 

 

 

 

Cracked

 

Weld

 

 

 

 

 

 

 

Parts

 

Terminals

14-Pin Cord

Torch, Electrode Holder,

 

 

 

 

Or Gun Cable

 

 

 

 

 

 

 

 

6 Months

 

 

 

 

 

Blow Out

During Heavy

 

 

 

 

Or

 

 

 

 

Service,

 

 

 

OR

Vacuum

 

 

 

Clean Monthly

 

 

 

 

Inside

 

 

 

 

 

 

 

4-2.

Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

Remedy

 

 

 

 

 

No weld output; unit completely inoperative; pilot light

Place Power switch in the On position (see Section 3-1).

not on.

 

 

 

 

 

 

 

 

 

 

Place line disconnect switch in the On position (see Section 2-9).

 

 

 

 

 

 

 

 

 

Check line fuse(s); replace if open or reset circuit breaker(s) (see Section 2-9).

 

 

 

 

 

 

 

 

 

Check for proper input connections (see Section 2-9).

 

 

 

 

 

Erratic weld output.

Use proper size and type weld cable (see Section 2-6).

 

 

 

 

 

 

 

 

 

Clean and tighten all weld connections (see Section 4-1).

 

 

 

 

 

 

 

 

 

Check for proper input connections (see Section 2-9).

 

 

 

 

 

No open-circuit voltage; pilot light on; wire does not

Secure gun trigger connections or see gun Owner’s Manual.

feed.

 

 

 

 

 

 

 

 

 

 

Secure plug in Remote 14 receptacle RC3 (see Section 2-7).

 

 

 

 

 

No open-circuit voltage; pilot light on; wire feeds.

Thermostat open (overheating). Allow unit to cool.

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check contactor W.

 

 

 

 

 

Open-circuit voltage normal; pilot light on; wire does

Check gun or wire feeder Owner’s Manual.

not feed.

 

 

 

 

 

 

No 115 volts ac output at Remote 14 receptacle RC3.

Reset circuit breaker CB1 (see Section 3-1).

 

 

 

 

 

No 24 volts ac output at Remote 14 receptacle RC3.

Reset circuit breaker CB2 (see Section 3-1).

 

 

 

 

 