Milwaukee Jig Saw manual Extension Cords, Grounding, Symbology, Specifications

Models: Jig Saw

1 29
Download 29 pages 6.31 Kb
Page 4
Image 4

19. Blade depth and bevel adjusting lock-

20. Use extra caution when making a

ing levers must be tight and secure

"Plunge Cut" into existing walls or

before making cut. If blade adjustment

other blind areas. The protruding

EXTENSION CORDS

shifts while cutting, it may cause binding

blade may cut objects that can cause

and KICKBACK.

KICKBACK.

GROUNDING

Grounded tools require a three wire exten- sion cord. Double insulated tools can use either a two or three wire extension cord. As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage. Refer to the table shown to determine the required minimum

Guidelines for Using Extension Cords

• If you are using an extension cord out-

doors, be sure it is marked with the suffix

“W-A” (“W” in Canada) to indicate that it

is acceptable for outdoor use.

• Be sure your extension cord is prop-

erly wired and in good electrical

condition. Always replace a damaged

extension cord or have it repaired by a

WARNING

Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electri- cian if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the cord or plug is damaged. If damaged, have it repaired by a MILWAUKEE service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

Grounded Tools:

Tools with Three Prong Plugs

Tools marked “Grounding Required” have a three wire cord and three prong grounding

The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire con- nected to the tool's grounding system and must never be attached to an electrically “live” terminal.

Your tool must be plugged into an appropri- ate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in Figure A.

Double Insulated Tools:

Tools with Two Prong Plugs

Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association and the National Electrical

wire size.

The smaller the gauge number of the wire, the greater the capacity of the cord. For ex- ample, a 14 gauge cord can carry a higher current than a 16 gauge cord. When using more than one extension cord to make up the total length, be sure each cord contains at least the minimum wire size required. If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum wire size.

 

qualified person before using it.

Protect your extension cords from sharp

 

objects, excessive heat and

 

damp or wet areas.

Recommended Minimum Wire Gauge

for Extension Cords*

Nameplate

Extension Cord Length

Amperes

25'

50'

75'

100'

150'

 

 

 

 

 

 

0 - 2.0

18

18

18

18

16

2.1

- 3.4

18

18

18

16

14

3.5

- 5.0

18

18

16

14

12

5.1

- 7.0

18

16

14

12

12

7.1 - 12.0

16

14

12

10

 

12.1

- 16.0

14

12

10

 

 

16.1

- 20.0

12

10

 

 

 

 

 

 

 

 

 

 

*Based on limiting the line voltage drop to five volts at 150% of the rated amperes.

plug. The plug must be connected to a prop- erly grounded outlet (See Figure A). If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of electric shock.

Code. Double Insulated tools may be used in either of the 120 volt outlets shown in Figures B and C.

READ AND SAVE ALL INSTRUCTIONS FOR FUTURE USE.

Symbology

 

Double Insulated

 

Volts Alternating Current/

 

 

Direct Current

 

 

 

 

 

 

 

 

Underwriters Laboratories, Inc.

 

Volts Alternating Current

 

 

 

 

 

Amps

 

No Load Revolutions per

 

 

 

Minute (RPM)

Fig. A

Fig. B

Fig. C

 

 

Specifications

 

 

 

 

 

 

 

 

 

Cat.

Volts

No Load

Blade

Arbor

Depth of Cut

Depth of Cut

No.

 

RPM

Size

 

At 90°

at 45°

 

 

 

 

 

 

 

6390-20

120 AC/DC

5 800

7-1/4"

5/8"

0 to 2-15/32"

0 to 1-13/16"

6394

120 AC Only

5 800

7-1/4"

5/8"

0 to 2-15/32"

0 to 1-13/16"

 

 

 

 

 

 

 

6

7

Page 4
Image 4
Milwaukee Jig Saw manual Extension Cords, Grounding, Symbology, Specifications