2.5.Rear Panel

ACasters.

BTerminal Block for Input/Output Connections.

CMaintenance Bypass Switch.

DInput Circuit Breaker.

EEPO (Emergency Power Off) Port.

FOption Slot 2 is for the SNMP card and the Programmable Relay card only.

GOption Slot 1 is for other option cards except the SNMP card and the Programmable Relay card.

HConnectors for Maintenance Bypass and Parallel Redundant function.

IDipswitch for the Parallel Redundant function.

NOTE: The dipswitch must be in the Off position when the Parallel function is not being used.

JRS232 Port for monitoring and control.

KDipswitch for FACTORY USE ONLY.

LCooling fans.

MCable tie downs.

NBattery Connector for connecting an External Battery Pack.

OBattery Connector for Daisy Chaining an additional External Battery Pack or for connecting an External Charger.

PCaster cover plate.

10

3 Installation and Operation

(QUALIFIED SERVICE PERSONNEL ONLY)

Be sure to read the Installation Placement and all of the CAUTIONS and the WARNINGS before installing the UPS system. Packages that are crushed, punctured, or torn such that the contents are revealed should be set-aside in an isolated area and be inspected by a qualified person. If the package is deemed to be not usable, immediately contact the freight carrier and the place of purchase. USE CAUTION: This UPS system is extremely heavy. Always use the appropriate number of personnel when handling the UPS system.

3.1.Unpacking

3.1.1Cut the banding straps and discard them.

3.1.2Lift the cardboard carton upwards off the packaging crate.

3.1.3Cut the banding strap. Remove the ramp and the corner post. Remove the side blocks. Use a screwdriver to remove the end stop.

3.1.4Place the ramp against the pallet. Remove the metal bracket and insert as shown to secure the ramp to the pallet.

3.1.5Push the unit slowly down the ramp.

3.1.6After removing your UPS from the packaging crate, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. The packing materials that your UPS system was shipped in are carefully designed to minimize any shipping damage. In the unlikely case that the UPS system needs to be returned to the manufacturer, please use the original packing material. Since the manufacturer is not responsible for shipping damage incurred when the system is returned, the original packing material is inexpensive insurance.

PLEASE SAVE THE PACKING MATERIALS!

3.1.7Standard Package includes: User's Manual

Warranty and Platinum Protection documents Power Monitoring software CD with RS232 cable One set of Accessories

11

Page 7
Image 7
Minuteman UPS ED6200T, ED6000T Installation and Operation, Rear Panel, Unpacking, Qualified Service Personnel only

ED6200T, ED6000T specifications

The Minuteman UPS ED6000T and ED6200T are robust uninterruptible power supply (UPS) systems designed to offer reliable protection for sensitive electronic equipment. These units stand out in the market for their enhanced features, advanced technologies, and exceptional performance.

The core design of the ED6000T and ED6200T integrates a pure sine wave output, ensuring compatibility with all types of devices, including sensitive electronics and critical infrastructure. This feature minimizes electrical distortion, providing protection against damage from power fluctuations. They deliver up to 6000VA and 6200VA of power respectively, making them suitable for small to medium-sized data centers, telecommunications equipment, and critical servers.

One key characteristic of these models is their comprehensive LCD display that provides real-time monitoring of UPS status, battery charge level, load percentage, and other essential diagnostics. This user-friendly interface makes it convenient for users to assess performance at a glance and manage their power protection strategies effectively.

Both models employ advanced battery management technologies, including Smart Battery Management that extends battery life through optimized charging cycles. This is crucial for maintaining reliability, especially in environments where power outages can be frequent and disruptive. The UPS units also feature an automatic voltage regulation (AVR) system that corrects minor voltage fluctuations, maintaining consistent output without switching to battery mode.

Additionally, the ED6000T and ED6200T incorporate the Minuteman Green Power UPS™ technology, designed to minimize energy consumption and reduce heat output, thus contributing to lower operational costs and environmental sustainability. With an energy-efficient design, they are not only financially beneficial but also eco-friendly.

Connectivity options are another highlight, as both models feature multiple outlets, including surge-protected and battery backup outlets, ensuring plenty of connections for various devices. They are equipped with USB and serial communication ports that allow for seamless integration with monitoring and management software, thereby enhancing their functionality in networked environments.

In conclusion, the Minuteman UPS ED6000T and ED6200T are powerful solutions for businesses seeking reliable power protection. With their pure sine wave output, advanced battery management, user-friendly interfaces, and energy-efficient designs, they represent a solid investment for safeguarding critical electronics against power interruptions.