EN-37
Indicators

POWER

Steady
green
or
Steady red
Steady red
Steady
green
Steady red
Steady red
Blinking
green/red
Blinking
green/red

STATUS

Blinking orange
Blinking green
Blinking green/red
Blinking red
Steady red
Off
Steady
or
Blinking

CONDITION

Abnormal temperature
• The ventilation grilles are clogged with dust or dirt.
• The room temperature is high.
• The filter is dirty.
The protection circuit is working or the lamp is in an
abnormal condition.
The lamp or cover isn’t closed.
Abnormal.
POSSIBLE SOLUTION
• Clean the ventilation grilles.
• Relocate the projector to a cooler place.
• Clean the filter.
• Wait until the STATUS indicator goes out,
then press the POWER button.
• If the above solution is not effective,
replace the lamp.
Replace the lamp.
Change with a new lamp if this problem
recurs.
Close the cover correctly.
Contact your dealer.
Duration when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be
shorted.
*
1
*
2
When LAMP MODE is set to STANDARD, this duration will be shorted up to 2000 hours.
Lamp operation time warning. (Total lamp operation time
reached 3000 hours*1 while the power was on.)
Lamp operation time warning. (Total lamp operation time
reached 3000 hours*1 while the power was off.)
Lamp operation time warning. (Total lamp operation time
reached 4000 hours*1*2 while the power was off.)

This projector has 2 indicators, each of which shows the operation condition of the projector.

The following offer solutions to possible problems. If these problems persist, turn the projector off and consult your

dealer.

Normal condition

Abnormal condition

STATUS indicator

POWER indicator

POWER

Steady
red
Steady
green

S TA TUS

Off
Steady
green

CONDITION

Stand-by
Lamp stand-by for power-on (about 1 minute)
The power is on. (Normal condition)

NOTE

The power cannot be turned off by pressing
the POWER button.
For the first one minute, the power cannot be
turned on by pressing the POWER button.
Steady
green
Blinking
Lamp stand-by for power-off (about 2 minutes)
r
green