5 - 16
5. PARAMETERS
Class No. Symbol Name and function Initial
value Unit Setting
range Control
mode
Expansion parameters 1
43 *DI2 Input signal selection 2 (CN1-4)
Allows any input signal to be assigned to CN1-pin 4.
Note that the setting digit and assigned signal differ according to the
control mode.
Position
control mode Input signals of
CN1-pin 4
selected.
Internal speed
control mode
0 0
Signals that may be assigned in each control mode are indicated
below by their symbols.
Setting of any other signal will be invalid.
Set value (Note) Control mode
PS
0
1
2
3
4
5
6
7
8
9
SON SON
RES RES
PC PC
SP1
SP2
ST1
ST2
CR CR
ASP3
B
C
DTL1
ECDP
CM1
CM2
TL1
CDP
F
Note: P: Position control mode
S: Internal speed control mode
This parameter is unavailable when parameter No.42 is set to assign
the control change (LOP) to CN1-pin 4.
This parameter is unavailable when parameter No. 48 is set to assign
the Forward rotation stroke end (LSP) and Reverse rotation stroke end
(LSN) to be assigned to CN1-pin 4.
0111 Refer to
Name
and
function
column.
P S